Published 10/2026
Set on holes and overburn
Creating holes for saddle set ons requires a balance between bevel relative to the mating pipe and overburn in the hole gutters. Allowing a more negative torch angle can reduce the bevel relative to the mate part, but it can also cause the cut to extend deeper into the gutters than intended.
Bevel on the part being cut. This describes the bevel made in the pipe containing the hole.
Bevel relative to the mate part. This describes the cut face relative to the saddle pipe that will sit on the hole. A zero Bevel Angle setting does not guarantee zero bevel against the mate part when the negative torch angle is limited.
Reduce negative bevel to reduce overburn in the hole gutter
Minimum bevel against the mate part. Figure 1 shows an ideal cut geometry that requires an extremely negative torch angle in the gutters. In practice, the torch can deflect off the pipe and overburn, cutting the gutters deeper than desired.
Reduced overburn. Figure 2 shows a more common compromise. Limiting how far negative the torch can go reduces the overburn, but leaves more bevel relative to the mate part in the gutters. Increasing the magnitude of Negative Bevel Limit allows a more negative angle and can reduce that relative bevel, but increases overburn.
Both diagrams use Cut Surface set to OD. The OD is the fit line where the inside diameter of the saddle pipe matches the hole. Fixed Bevel is unchecked so the torch can change angle during the cut; checking it would create no bevel relative to the part being cut, but this would result in a large bevel in the gutters relative to the mate part.
The examples show Negative Bevel Limit values of -60 for the more negative cut and -15 for the compromise. The Diameter shown is the inner diameter of the mate pipe, calculated as 6.625 - (0.28 x 2) = 6.065 inches for the illustrated 6-inch Schedule 40 pipe.
If the required fit calls for minimum bevel relative to the mate part in the gutters, an ellipse may help compensate for overburn. With an ellipse the negative bevel limit can be at or closer to -60, and you can shorten the ellipse dimension across the pipe to compensate for the resulting overburn. Finding an acceptable result requires trial and error.
Also, adjusting feedrate, gas selection, and gas pressure
may also help reduce overburn, but these changes require experimentation.
An extremely negative torch angle minimizes bevel against the mate part but can overburn the gutters. Example Negative Bevel Limit is -60.
Limiting the negative torch angle leaves more bevel against the mate part in the gutters. Example Negative Bevel Limit is -15.