Enterprise v4.1 Change List
General
New Features
- Expose Right and Left cut end notes as individual columns in the Scheduled Parts Tab
- Allow a remote user to bypass the folder access denied message on app startup
- Add Parameter to Rectangle cut so bevel is against part instead of intersecting tube
- Discrete control of lead-in for straight cuts
- Add additional fields to cuts tree table in designer
- Prevent Enterprise from nesting a part with a hole in the dead zone when using the Far End feature.
- When nesting parts, buffer all external status reporting and do not send until "done"
- Display part length as feet and inches in the nesting tab "Part Info"
Fixes
- The close button next to Auto Fit Columns doesn't close anything
- In the scheduled parts dropdown from the design tab, the part status is not updating until refreshed
- Move Enterprise logs folder from user folder to common application folder
- Show Filters becomes unchecked when you clear filters
- Force grid checkboxes to display even if current layout hides them
- Classroom - Student NetBIOS machine name check is too stringent for Windows 10/11
- Torch 45° is out of proportion in animation
- Splitters on Machine Settings tab, Cut Designer control and other tabs not allowing user to move splitter bars, not resizing correctly, not setting back to default
- When loading to machine warn user if torch processes are already assigned to Pipe/Parts/Cuts
- Suspend inputs when Create NC File and probably other buttons are clicked
- Animation is not recognizing a skipped cut
- A filter created in the nesting tab shows up in all designs expanded view of scheduled parts
- A single non-end-cut does not show up in display until you create one end-cut
- Error message when trying to view the flat cut
- The Next button in animation view no longer works
- Unable to group select in the part design grid with checkbox
- Deprecate the Auto Print checkbox in the create NC file window
- Remove the Create Pipe button on the upper right taskbar
- Repad cutting issue
- Left edge parameters are not all being displayed for different HPP torch tilt types cuts
- Single Cut display in Designer is not offsetting by Y for any machine.
- Mirroring a part: Mirroring a miter is not mirroring correctly
- The catch for preventing cuts in the dead zone is ignored with incremental nesting
Importing
New Features
- BuildCentrix support
- Part cuts can be edited or deleted before import
- IsoViewer ‘raw spool” visual import data viewer
- Legacy importers now support mapping and lookup tables
Fixes
- Acorn: Update to fully support new PCD 6.0 schema items
- MSuite: Mate1Angle and FieldLength are backwards for some spools
- MSuite: API level logging
- MSUITE: Not getting status updates from PypeServer
- MSuite: Update login and start shift workflows
- MSuite: CSV imported parts do not get marked as completed In MSuite when cut
- PCF: Create a new option to allow the user to uncheck a TEE-SET-ON as a pipe
- PCF: Ship Constructor import has incorrect part length
- PS Connect: 4 & 5" nominal pipe sizes are not being converted to NPS on import
- STEP: Importer not correctly identifying an end-cut
- STEP: Importer is failing to load settings. Is trying to convert a percentage value through units
- STEP: GCode cut imported through Importer is not getting a Feedrate in the GCode
- Stratus: (Cutlist) is no longer available in mapping
- Stratus: Reset account data after an API key change
- Stratus: Support features - Tool message management, API logging
- Stratus: import reports No parts found
- Tekla: Import Mate Angle is 22.5. Customer states that it should be 67.5
- Tekla: Import with 2 miters incorrect length
- Tekla: Ends rolled incorrectly on import
- Changing part status from a remote seat will not update the status in Stratus
- Remove legacy custom CSV importers
- Integrate IsoViewer into Import Manager for customers who use coordinate based importers
- Importers don't use cut defaults
- Error loading pipes from a template
Label Print
New Features
- Labels for stock pipes stored in pipe Inventory
- Labels for drop pipes after dismounting from machine
- Label Designer
- Search fields by typing first letter of the field name
- Allow multi-select section for group editing / moving
- Allow height and width controls to go less than 1"
- Should be able to delete label template items by hitting delete key
- Replace label template parameter picker up/down buttons with scroll bar
Fixes
- Fixed support for NiceLabel custom VB scripts.
- Label template reverts to a random template when the printer is changed
- Label template editor doesn't use sample data when test printing
- The show Windows Print Dialog is being ignored
- Do not automatically print labels for previously cut parts
- Label Template Designer-font size is not dynamically changing
- Convert Label Templates loop
- Importing a label template doesn't give you the option to save
- Changing the file name on an exported label template, will not import
- Deprecate the Auto Print checkbox in the create NC file window
- Label Print - Do not display "blank" QR Codes when the source value is null
- Setting Part Label to print after cut erases all the data
- Fails to parse label template when fields have same starting chars
Machine
New Features
- Chuck “dead-zone” cut support
- Implement line etching in EdgeConnect/XPR/Machitech
- Discrete control of lead-in for straight cuts
Fixes
- HPR G59 Process Variable use in Edge Connect controller NC code
- Machitech machine bring-up at TPH
- Lincoln Fineline fail does not produce actionable message to user
- HPR G59 Process Variable use for Edge Connect Controllers
- Switch Edge Connect to using M29 mode
- Persist Torch Process selection (GUID) on the pipe or part after user sends to machine once
- No prompt that a hole is being cut in the dead-zone for HGG machines
- Prevent Enterprise from nesting a part with a hole in the dead zone when using the Far End feature
- Machitech/Edge Connect Beveling Issue
- Create ability to remove M0 stops before cutting on Vernon Mini
- HGG - Delete any machine status files found during NC Manager file sync cycle
- HGG ProCAM reporting (.json.HGG) files no longer include the PipeID field
- Repad cutting issue
- Lone Star Edge Connect Controller Basic Bring-up
- Lone Star Magnum bring up with Slider Tilt head (Early July 2023 machine)
- Add stop for Fineline code to stop for user to set the torch type (Cut or etch)
- When loading to machine warn user if torch processes are already assigned to Pipe/Parts/Cuts
- Vernon 5Ax machine configured in Imperial and writing Metric .nc files, is not outputting Z height in metric to the NC files
- Fineline process selector is not initializing correctly on second part initialization
- Fineline Filtering is not filtering correctly in Process Selector
- Add process checks for material and wall thickness match before loading (Fineline, XPR)
- Vernon 5 Axis & Dynamic Tilt Torch Settings, Tip Geometry tab is hiding numeric input
- Vernon 5ax output is not using/responding to MachineProperty.AdjustSpeedByStepCount
- Vernon Torch Settings Dwell time setting is not updated when it's set in the dialog box
Related Articles
Enterprise v4.2 Change List
General New Features Show left and right cut end notes as individual columns in the Scheduled Parts tab Allow a remote user to bypass the folder access denied message on app startup Status Messages button added to status bar for viewing status and ...
Enterprise v4.4 Change List
General New Features Support for switching between Enterprise Site databases Systems health check and repair tool Print Cut Sheets and Burned Metal reports from Nesting, Pipe and Machine Tab Remote seats and Training program no longer require a ...
Enterprise v4.3 Change List
General New Features CodeMeter updates now run in unattended mode for organizations that manage their software deployments. Fixes Change release note links to point to documents on Support Site Unable to nest part on a new pipe from the Design Tab ...
Enterprise Architecture
Overview PypeServer Enterprise is a Windows application hosted on a computer with an Intel-based I-7 or better processor, 32GB of RAM and SSD storage running Windows 11 Professional. This computer is stored in an industrially enclosed kiosk that sits ...
Installing Enterprise
Installing Enterprise Installing Enterprise Install a License Seat At least one Enterprise seat must host a CodeMeter License Server that manages PypeServer licenses. This comes preinstalled on the Kiosk system provided by PypeServer, but it can be ...